The Conductor of Some Special Points in P^2
スポンサーリンク
概要
- 論文の詳細を見る
We describe a way of calculating the conductor of some special points in P^2, which are constructed by complete intersection finite sets of points. As examples, we calculate the conductor of pure configurations in P^2. Furthermore we give a necessary and sufficient condition for a pure configuration to have the Cayley-Bacharach property.
- 徳島大学の論文
- 1995-02-20
著者
-
Okuyama Hiroshi
Department Of Cardiovascular Surgery Jikei University School Of Medicine
-
Harima Tadahito
Department Of Management And Information Science Faculty Of Management And Information Science Shiko
-
Okuyama Hiroshi
Department Of Mathematical Sciences Faculty Of Integrated Arts And Sciences The University Of Tokush
-
Okuyama Hiroshi
Department Of Applied Chemistry Science University Of Tokyo
関連論文
- Logistic Time Constant of Isometric Relaxation Force Curve of Ferret Ventricular Papillary Muscle : Reliable Index of Lusitropism
- Three-Dimensional Images of Extra-Routine Grafts in CABG by Multidetector Computed Tomography
- Transmurally Difference in Crossbridge Dynamics and Sarcomere Shortening during Relaxation of Isovolumic Beat(Cardiac Function, Basic/Clinical 3 (M), The 69th Annual Scientific Meeting of the Japanese Circulation Society)
- OE-194 Harmonized Transmural Crossbridge Formation during Contraction, but Discordant Crossbridge Decay during Relaxation Analyzed in Beating Rat Heart at SPring-8(Cardiac Function, Basic/Clinical 1 (M) : OE24)(Oral Presentation (English))
- Detection of Transmural Cross-Bridge Formation of the Heart by Spring-8 X-Ray Diffraction
- Biosynthesis of Pinguisone in an Axenic Culture of the Liverwort Aneura pinguis
- Occurrence of (+)-α-Cedrene in Larix leptolepis Callus
- A Metastable Precursor in the Oxidation of Si(111)-(7 × 7)
- High Modulus Films of Polytetrafluoroethylene Prepared by Two-Stage Drawing of Reactor Powder
- Patient-prosthesis mismatch may be irrelevant after aortic valve replacement with the 19-mm Perimount pericardial bioprosthesis in patients aged 65 years or older
- Prevalence of pannus formation after aortic valve replacement : clinical aspects and surgical management
- Midterm Results of Mitral Valve Repair with the Carpentier-Edwards Rigid Ring
- Dispersion-Compensation Electron-Energy-Loss Spectrometer
- Mitral valve reconstruction : long-term results of triangular resection for degenerative prolapse
- Validity of identifying patient-prosthesis mismatch from the indexed effective orifice area
- Carpentier-Edwards Pericardial Aortic Valve in Middle-aged Patients : Comparison with the St. Jude Medical Valve
- Biosynthesis of Sesquiterpenes from Deuterated Mevalonates in Perilla Callus
- The Conductor of Some Special Points in P^2
- On the Poincare' Series of a Semigraded Module
- A Note on Conjectures of the Ideal of s-generic Points in P^4
- Increased Passive Stiffness of Cardiomyocytes in the Transverse Direction and Residual Actin and Myosin Cross-Bridge Formation in Hypertrophied Rat Hearts Induced by Chronic β-Adrenergic Stimulation
- Increased Passive Stiffness of Cardiomyocytes in the Transverse Direction and Residual Actin and Myosin Cross-Bridge Formation in Hypertrophied Rat Hearts Induced by Chronic β-Adrenergic Stimulation