Cooling Systems for IT Environment Heat Removal in (Internet) Data Centers(Environmental Engineering)
スポンサーリンク
概要
- 論文の詳細を見る
Internet Data Center (IDC) heat removal is one of the most essential yet least understood of all critical IT environment processes. The cooling of data centers has emerged as a significant challenge as the density of computing equipment increases. In this research, environmental aspects of energy consumption and load-profile were studied through the survey of domestic data centers that need all year round cooling load. The energy-using patterns of cooling system combined with real power density are compared and energy saving effects of data center is reviewed. All cooling systems use CRAC or CRAH units of some kind, which come in various capacities and remove the heat from the room. There are five heat removal methods and two common physical equipment arrangements that can be combined to create ten basic types of cooling systems. Air supply and air return systems each have three and four different configurations that can be combined to create thirteen basic types. An understanding of the many types of cooling/air distribution systems and their attributes can be used to develop guidelines for when each type should be used, and such guidelines are provided in this study for both raised floor and hard floor applications. The design criteria of cooling and air distribution systems were analyzed using quantitative data acquired by surveying 20 multi-megawatt data centers in Korea. It provides the best configurations and design criteria for different IT environments and common practices and equipment options that may increase cooling system availability.
- 社団法人日本建築学会の論文
著者
-
Kim Byungseon
Department Of Architectural Engineering Yonsei University
-
Cho Jinkyun
Senior Research Engineer, R & D Institute, Hanil Mechanical Electrical Consultants Ltd.
-
Lim Taisub
Department of Architectural Engineering, Yonsei University
-
Lim Taisub
Department Of Architectural Engineering Yonsei University
-
Cho Jinkyun
Senior Research Engineer R & D Institute Hanil Mechanical Electrical Consultants Ltd.:department
関連論文
- The Indoor Environment Measurement Analysis of Arcade-Type Markets in Korea(Environmental Engineering)
- Air Exchange Rate Analysis of The Arcade-Type Traditional Market Using Wind Tunnel Experiment and CFD Model(Environmental Engineering)
- Analyses on Thermal Insulation Performance of Earth-Covered Wall for Residential Underground Space by Using a Numerical Simulation Program(Environmental Engineering)
- Smoke Movement and Evacuation Time in the Arcade of a Traditional Market using Numerical Simulation(Environmental Engineering)
- Predicting Potential Condensation at the Inside Surface of the Glazed Curtain Wall of High-rise Residential Buildings(Environmental Engineering)
- A Study on Thermal Environment and the Design Methods to Save Energy in Small Glass-Skin Commercial Buildings(Environmental Engineering)
- Cooling Systems for IT Environment Heat Removal in (Internet) Data Centers(Environmental Engineering)