Measurement of Photoneutron Dose Produced by Wedge Filters of a High Energy Linac Using Polycarbonate Films
スポンサーリンク
概要
- 論文の詳細を見る
Radiotherapy represents the most widely spread technique to control and treat cancer. To increase the treatment efficiency, high energy linacs are used. However, applying high energy photon beams leads to a non-negligible dose of neutrons contaminating therapeutic beams. In addition, using conventional linacs necessitates applying wedge filters in some clinical conditions. However, there is not enough information on the effect of these filters on the photoneutrons produced. The aim of this study was to investigate the change of photoneutron dose equivalent due to the use of linac wedge filters. A high energy (18 MV) linear accelerator (Elekta SL 75/25) was studied. Polycarbonate films were used to measure the dose equivalent of photoneutrons. After electrochemical etching of the films, the neutron dose equivalent was calculated using Hp(10) factor, and its variation on the patient plane at 0, 5, 10, 50 and 100 cm from the center of the X-ray beam was determined. By increasing the distance from the center of the X-ray beam towards the periphery, the photoneutron dose equivalent decreased rapidly for the open and wedged fields. Increasing of the field size increased the photoneutron dose equivalent. The use of wedge filter increased the proportion of the neutron dose equivalent. The increase can be accounted for by the selective absorption of the high energy photons by the wedge filter.
- 2008-05-16
著者
-
Sharafi Ali
Department Of Radiology Iran University Of Medical Sciences
-
Shokrani Parvaneh
Department Of Medical Physicsand Engineering Esfahan University Of Medical Sciences
-
Sharafi Ali
Department Of Radiology Technology School Of Paramedicine Iran University Of Medical Sciences Hemmat
-
Hashemi-malayeri Bijan
Department Of Medical Physics Tarbiat Modares University
-
Hashemi Seyed
Department Of Medical Physics Tarbiat Modares University
-
Torkzadeh Falamarz
National Radiation Protection Department Iranian Nuclear Regulatory Authority Atomic Energy Organiza
-
RAISALI Gholamreza
Radiation Applications Research School, Nuclear Science and Technology Research Institute, Atomic En
-
Raisali Gholamreza
Radiation Applications Research School Nuclear Science And Technology Research Institute Atomic Ener
-
Hashemi Seyed
Department of Immunology, Faculty of Medical Sciences, Tarbiat Modares University
関連論文
- Effect of Transplantation of Mesenchymal Stem Cells Induced into Early Hepatic Cells in Streptozotocin-Induced Diabetic Mice
- Measurement of Photoneutron Dose Produced by Wedge Filters of a High Energy Linac Using Polycarbonate Films
- Effect of respiratory motion on quantitative myocardial gated SPECT : a simulation study
- Deployment of the meta heuristic Colonial Competitive Algorithm in synthesis of unequally spaced linear antenna array