SQUID ピコボルトメータを用いた非破壊検査における欠陥深さの推定
スポンサーリンク
概要
- 論文の詳細を見る
Eddy current testing utilizing a cooled normal pickup coil and a high-T_c superconducting quantum interference device (SQUID) picovoltmeter was performed both experimentally and analytically. In the experiment, we successfully detected a small crack on the back surface of the Cu plate by moving the coil in unshielded environment. First, we showed a method to avoid a drift of the detected signal that was caused by the variance of lift-off. Next, we clarified the dependencies of the detection signal on the excitation frequency and thickness of the Cu plate. It was shown that an optimum frequency that maximizes the detected signal exists. Since this frequency changed with the thickness of the Cu plate, the frequency dependence could be used to estimate the depth of the crack from the surface of the Cu plate. The experimental results were analyzed by taking account of the phase and amplitude of the signal field caused by the crack. Good agreement was obtained between experiment and analysis.
- 九州大学の論文
著者
-
楊 同青
九州大学大学院システム情報科学府電子デバイス工学専攻
-
楊 同青
九州大学大学院システム情報科学研究院電気電子システム工学部門
-
山崎 大輔
九州大学大学院薬学研究院製剤設計学分野
-
八尾 健一朗
九州大学大学院システム情報科学府電気電子システム工学専攻
-
山崎 大輔
九州大学大学院システム情報科学府電気電子システム工学専攻
関連論文
- SQUID を用いた磁気的免疫検査システムの開発
- P-175 ホリナートとフェニトインの薬物相互作用に関する基礎的検討(7.薬物相互作用(基礎と臨床)1,医療薬学の未来へ翔(はばた)く-薬剤師の薬剤業務・教育・研究への能動的関わり-)
- SQUID ピコボルトメータを用いた非破壊検査における欠陥深さの推定
- SQUIDピコボルトメータを用いた非破壊検査における欠陥深さの推定
- SQUIDピコボルトメータを用いた非破壊検査--周波数依存性を利用した欠陥深さの推定