Morphology of Thai Edentulous Mandible Using 3D Reverse Engineering : Relevance to Immediate Loading Dental Implant Design
スポンサーリンク
概要
- 論文の詳細を見る
The dimension and number of implants as well as the splinting concept of the superstructure are the impact factors of the immediate loading implant-supported prostheses. The purpose of this study is to determine the morphometric data of Thai lower edentulous jaws between two metal foramens for optimizing the design. Sixty-four Thai cadaveric edentulous mandibles were CT scanned and 3D models were reconstructed. Arch forms, dimensions, and the area of the greatest concavity in the body of the mandibles between the metal foramens were defined in geometric terms based on reverse engineering methods. The arch forms, represented by average values of angle and distance of panoramic arc, were 116.4±9.5 degrees and 46.7±3.9mm respectively. The dimensions of the mandibles, determined by the height and width of the body of the mandibles as well as the angle between the axis of the mandibular body to the mandibular plane, were 25.3±0.6mm, 11.6±0.6mm and 61.3±1.7 degrees respectively. The area of greatest concavity was 8.3±1.9mm. Morphology of the Thai edentulous mandible determines the maximum length of an implant placed for immediate loading protocol as 17mm, with a maximum diameter of 3.5-5mm. The maximum number of implants that can be placed in the anterior region is 5.
- 一般社団法人日本機械学会の論文
- 2006-09-15
著者
-
Suwanprateeb Jintamai
National Metal And Material Technology Center (mtec)
-
KASEMSARN Suthasinee
Department of Prosthodontics, Faculty of Dentistry, Mahidol University
-
MAHAISAVARIYA Banchong
Department of Orthopaedic Surgery, Faculty of Medicine, Siriraj Hospital, Mahidol University
-
SITTHISERIPRATIP Kriskrai
National Metal and Material Technology Center (MTEC)
-
Kasemsarn Suthasinee
Department Of Prosthodontics Faculty Of Dentistry Mahidol University
-
Mahaisavariya Banchong
Department Of Orthopaedic Surgery Faculty Of Medicine Siriraj Hospital Mahidol University
関連論文
- COATING OF HYDROXYAPATITE BY SOL-GEL TECHNIQUE : INFLUENCE OF HYDROLYSIS AGENTS
- INFLUENCE OF SOAKING SOLUTIONS ON LOW TEMPERATURE PHASE CONVERSION TO CALCIUM PHOSPHATE OF 3DP CALCIUM SULFATE OBJECT
- Morphology of Thai Edentulous Mandible Using 3D Reverse Engineering : Relevance to Immediate Loading Dental Implant Design
- Influence of Lateral Muscle Loading in the Proximal Femur after Fracture Stabilization with a Trochanteric Gamma Nail (TGN)(Bioengineering)
- Stress Distributions in Trochanteric Gamma Nail (TGN) During Walking : A finite element study(Orthopaedic Biomechanics)
- Influence of Lateral Muscle Loading in the Proximal Femur and Implant after Stabilization with a Trochanteric Gamma Nail (TGN)(Orthopaedic Biomechanics)
- ACELLULAR BIOACTIVITY OF 3DP HYDROXYAPATITE AND APATITE-WOLLASTONITE GLASS CERAMIC REINFORCED HYDROXYAPATITE