Extraction of LRGC Matrices for 8-Coupled Uniform Lossy Transmission Lines Using 2-Port VNA Measurements (Electronic Components)
スポンサーリンク
概要
- 論文の詳細を見る
The electrical parameters (8×8 LRGC matrices) of 8-coupled uniform lossy transmission lines were extracted from 40 Sparameter values measured by using 2-port VNA measurements, where all the ports other than 2VNA ports were terminated by 50 ohm chip resistors. It was assumed in the extraction step that the transmission lines are weakly-coupled, and that the resistance values of all the termination chip resistors are exactly 50 ohms with the second reflections neglected. Comparison of the extracted LRGC matrix components with those from a commercial 3D field solver revealed on average and a maximum relative difference of 2.45% and 7.66%, respectively. In addition, the time-domain crosstalk voltage waveforms in the measured data and those in the SPICE simulation results using the extracted LRGC parameters agreed very well with the average difference and the maximum relative difference in peak crosstalk voltages of 4.15% and 9.68%, respectively.
- 社団法人電子情報通信学会の論文
著者
-
Lee Hyun
The Department Of Electronic And Electrical Engineering Pohang University Of Science And Technology
-
Park Hong
The Department Of Electronic And Electrical Engineering Pohang University Of Science And Technology
-
Lee Kyoungho
The Department Of Electronic And Electrical Engineering Pohang University Of Science And Technology
-
JUNG Hae
the Department of Electronic and Electrical Engineering, Pohang University of Science and Technology
-
Jung Hae
The Department Of Electronic And Electrical Engineering Pohang University Of Science And Technology