Vibration Isolation for Seismocardiogram Measurement in the OpenMRI-Guided Operating Theater(<Special Issue>Bioengineering)
スポンサーリンク
概要
- 論文の詳細を見る
The purpose of this study is to establish a method of measuring precisely the seismocardiogram (SCG) of a patient who lying in an open magnetic resonance imaging (openMRI) machine for myocardial ischemia monitoring during surgery. Vibration isolation was examined by analyzing the gantry vibration during MRI scanning and the SCG of a healthy volunteer. The MRI gantry vibration had maximum amplitude of 2.5 m/s^2, which are several peaks more than 100 Hz up to 500 Hz. Up to 94% reduction in amplitude was observed in the patient bed vibration under both T1-weighted and T2-weighted sequences. The power spectrum center of the patient bed vibration was more than 30 Hz. The maximum amplitude of SCG was 0.92 m/s^2 and a FFT analysis revealed that the SCG was not higher than 25 Hz. The signal-to-noise ratio between the SCG and the patient bed vibration was calculated to be from 4 to 7. These results demonstrate that the peak acceleration of the SCG can be monitored during openMRI scanning. In conclusion, vibration analysis showed the feasibility of using the piezoelectric acceleration sensor for seismocardiogram measurement in the openMRI-guided operating theater.
- 一般社団法人日本機械学会の論文
- 2003-12-15
著者
-
ISEKI Hiroshi
Faculty of Advanced Techno-Surgery, Institute of Advanced Biomedical Engineering and Science, Tokyo
-
Iseki Hiroshi
Faculty Of Advanced Techno-surgery Institute Of Advanced Biomedical Engineering And Science Tokyo Wo
-
Naemura Kiyoshi
School Of Bionics Tokyo University Of Technology
-
Iseki Hiroshi
Faculty Of Advanced Techno-surgery Institute Of Advanced Biomedical Engineering And Science Tokyo Wo
関連論文
- Shift of the Pyramidal Tract During Resection of the Intraaxial Brain Tumors Estimated by Intraoperative Diffusion-Weighted Imaging
- Three-Way Bipolar Forceps : A Novel Bipolar Coagulator System for Nerve Stimulation and Detection of Nerve Potentials
- Intelligent Operating Theater Using Intraoperative Open-MRI
- Preoperative mapping for patients with supplementary motor area epilepsy : multimodality brain mapping
- P-MB-02 ANALYSIS OF CHEST SURFACE VIBRATION FOR PERIOPERATIVE MYOCARDIAL ISCHEMIA MONITOR IN THE OPENMRI-GUIDED OPERATING THEATER
- Vibration Isolation for Seismocardiogram Measurement in the OpenMRI-Guided Operating Theater(Bioengineering)
- Wireless Modification of the Intraoperative Examination Monitor for Awake Surgery : Technical Note
- Gamma Knife Radiosurgery for Benign Cavernous Sinus Tumors : Treatment Concept and Outcomes in 120 Cases
- Patterns of Intracranial Glioblastoma Recurrence After Aggressive Surgical Resection and Adjuvant Management : Retrospective Analysis of 43 Cases