安全性からみた階段のすべりの評価方法の提示 : 安全性からみた階段のすべりの評価方法に関する研究(その3)
スポンサーリンク
概要
- 論文の詳細を見る
The purpose of this study is to establish evaluating method of slip resistance of stairway treads from a viewpoint of safety. In this paper, Part 3, following results were obtained. (1) The evaluating scales of slip resistance of stairway treads were composed (nine scales in all), by the method of sensory test. In composing these scales, some actual factors were considered, namely, proportion of tread and riser, kinds of finishing materials of treads and nosing, and, kinds of footwears. (2) The physical values of slip resistance of stairway treads which well correspond to each evaluating scales were newly established, on basis of the results of former paper (Part 2), and these values were named 'C.S.R・S'. (3) The evaluating indexes and method of slip resistance of stairway treads were presented by using the evaluating scales and 'C.S.R・S'.
- 社団法人日本建築学会の論文
- 1988-01-30
著者
-
三上 貴正
東京工業大学大学院情報理工学研究科
-
小野 英哲
東京工業大学工学部建築学科
-
大野 隆造
神戸大学
-
武田 清
清水建設株式会社
-
大野 隆造
東京工業大学:(現)神戸大学:日本建築学会
-
小野 英哲
東京工業大学
-
三上 貴正
東京工業大学
関連論文
- 床のすべりの評価における床表面介在物の標準化に関する研究
- 1329 コンクリート表層部モルタルの密実性がその耐久性に及ぼす影響 : 吸水性・塩分浸透性について
- コンクリート表層部モルタルの密実性に及ぼす単位水量の影響 : 体積吸水率からの基礎的考察
- 1118 コンクリート表層部モルタルの耐久性に及ぼす単位水量の影響 : 耐塩害性、耐酸性、耐凍害性に関する基礎的考察
- 1117 コンクリート表層部モルタルの密実性に及ぼす単位水量の影響 : 見掛気孔率からの考察
- 安全性からみた浴室床および浴槽底のすべりの評価方法に関する研究 : その2 すべりの評価指標および評価方法の提示
- 1359 視覚的観点からみた建築物床仕上面の凹凸の評価方法に関する研究 : 凹凸の観察条件の設定
- 1356 建築物床のすべり抵抗の測定における媒介物の標準化に関する研究 : 水類、油類、洗剤類の代替媒介物の提示
- 1291 建築物床のすべり抵抗の測定方法の標準化に関する研究 : 土砂・ほこりの代替媒介物の提示
- 床仕上材料のすべりやすさと歩行特性の関係に関する基礎的研究