X-Ray Radiation of the Plasma Focus with Inverse Pinch Switch
スポンサーリンク
概要
- 論文の詳細を見る
X-ray radiation characteristics of the plasma focus with inverse pinch switch was investigated. The plasma focus device power with capability of 20 kJ contains a 40 kV condenser power supply and adopts a new type of switch system, The mechanism of X-ray radiation was analyzed using a pair of detectors. The variation of X-ray radiation as a function of the position of emitted X-ray and the shape of electrode was examined closely using the time-integrated method. By analyzing the mechanism, we found that the X-ray radiation has three peaks in the optimal plasma focus condition with the middle one being m = 0 instability.
- 社団法人応用物理学会の論文
- 1999-02-15
著者
-
Park D
Kyungpook National Univ. Daegu Kor
-
Park Duck
Department Of Physics. Kyungpook National University
-
Choi Woon
Department Of Ophthalmic Optics Kimcheon College
-
PARK Duck
Department of Physics, College of Education, Kyungpook National University
-
Choi Woon
Department of Electronics Engineering and Computer Science, Fukuoka University
関連論文
- Correlations between Argon Ion Beams and X-Rays in a Plasma Focus
- X-Ray Radiation of the Plasma Focus with Inverse Pinch Switch