Measurements of Plasma Flow Velocity in DC Plasma Jets Using Perpendicular and Parallel Mach Probes
スポンサーリンク
概要
- 論文の詳細を見る
A rotating electric probe system has been developed to measure the parameters of spray plasma jets from a dc plasma torch at atmospheric pressure. Four different types of unmagnetized single probes have been used for the diagnostics of high power-flux plasma-two probes are mutually perpendicular ('perpendicular mach probe') and the remaining two are oppositely directed to each other ('parallel mach probe')-to measure the plasma flow velocity and density along the axial and radial directions of the plasma flame. Near the nozzle exit of a 15 kW plasma torch, plasma flow velocity, density and electron temperature are measured as〜910 m/s, 4×10^<13>cm^<-3> and 4.7 eV, respectively.
- 社団法人応用物理学会の論文
- 1995-08-15
著者
-
Hong S‐h
Seoul National Univ. Seoul Kor
-
Chung K‐s
Seoul National Univ. Seoul Kor
-
Chung Kyu-sun
Electric Probe Applications Laboratory (epal) Hanyang University
-
Chung Kyu-sun
Department Of Nuclear Engineering Hanyang University
-
HONG Sang-Hee
Department of Nuclear Engineering, Seoul National University
-
CHUNG Kie-Hyung
Department of Nuclear Engineering, Seoul National University
-
Hong Sang-hee
Department Of Nuclear Engineering Seoul National University
関連論文
- Determination of Plasma Flow Velocity by Mach Probe and Triple Probe with Correction by Laser-Induced Fluorescence in Unmagnetized Plasmas
- Optimization of Hanyang University Plasma Focus Device as a Neutron Source
- Characterization of 'Hanbit' ECR plasma by using electric probe system
- Measurements of Plasma Flow Velocity in DC Plasma Jets Using Perpendicular and Parallel Mach Probes
- Fluid Analysis of the Effect of Ionization on Measurement of Plasma Flow in the Magnetized Presheath
- An Analytical Fluid Theory for the Simultaneous Measurement of Cross-Field Viscosity and Parallel Flow Velocity in Magnetized Plasma
- Comparison between Laser Thomson Scattering and Spectroscopic Measurements in Low Temperature Helium Plasmas in Divertor/Edge Simulator MAP-II
- Fluid Analysis of the Effect of Ionization on Measurement of Plasma Flow in the Magnetized Presheath
- Development of Heat Flow Measurement using Thermal Probe Method in Divertor Simulator MAP-II