A gridded ^3He ionization chamber had about 1-2% energy resolution, and was suitable for neutron spectroscopy of DD neutrons to measure the ion temperature. The gridded ^3He ionization chamber was used to measure the neutron spectra on the tokamak fusion test reactor (TETR) during 1987. The ion temperature was deduced for one set of ohmically heated plasmas and agreed within 20% with that measured by other diagnostics. The deuterium concentration n_d/n_e and Z_<eff> were estimated with 40% uncertainty from the ion temperature measured with the neutron spectroscopy and the neutron source strength measured with fission chambers.
- 社団法人応用物理学会の論文
- 1990-03-20
著者
-
Nishitani Takeo
Department Of Large Tokamak Research Naka Fusion Research Establishment Japan Atomic Energy Research
-
Nishitani Takeo
Department Of Fusion Engineering Research Naka Fusion Research Establishment Japan Atomic Energy Res
-
STRACHAN J.
Plasma Physics Laboratory, Princeton University
関連論文
- Active Beam Scattering Method for Measurement of Ion Temperature in JFT-2 Tokamak Plasma
- Evaluation of Shutdown Gamma-ray Dose Rates around the Duct Penetration by Three-Dimensional Monte Carlo Decay Gamma-ray Transport Calculation with Variance Reduction Method
- Neutron Spectroscopy with a ^3He Ionization Chamber on TFTR