Treeing in Solid Insulator
スポンサーリンク
概要
- 論文の詳細を見る
The mechanism of dendritic growth of discharge, or "Treeing" in solid insulator was investigated and the following conclusions were obtained. In the first stage of "Treeing", there occurs pure electronic breakdown due to ionization by collision of electrons. In the second stage rupture of chemical bonds by electron collision occurs. Then the processes produce molecules of lower molecular weight or gas phase. The existence of these processes were confirmed in consequence of the growth of bubbles from "Treeing" by heating Plexiglas immediately after the occurrence of "Treeing" up to a temperature near its softening point.
- 社団法人応用物理学会の論文
- 1965-12-15
著者
-
Mitsui Hideo
Electrical Engineering Department Musashi Institute Of Technology
-
TORIYAMA Yotsuo
Electrical Engineering Department, Musashi Institute of Technology
-
Toriyama Yotsuo