This paper discusses the loop tracer methods of measuring the anisotropy field H_k in permalloy thin films for selecting the most suitable method for automation. It is assumed that the films have a low dispersion. Practical details and results of investigations are given. Some considerations which differ from accepted views are also pointed out.