十勝沖地震における八戸日赤病院 (無被害) の検討
スポンサーリンク
概要
- 論文の詳細を見る
Many structures were damaged by the earthquake off Tokachi in Japan in 1968. But some structures were not damaged by this earthquake, and Hachinohe Nisseki Hospital was one of them. It is important to study not only structures which were damaged, but also those which were not damaged. It is interesting to study Hachinohe Nisseki Hospital by a dynamic analysis. This Hospital is 7 story reinforced concrete structure, and is designed statically in conformity to the seismic coefficient 0.2 which is decided in Japanese building code. In this study, the linear and tri-linear response analysis of this structure are executed. As the result of the response analyises, it is presumed that the maximum acceleration of the Tokachi earthquake which this structure was subjected to would be 80 gal.
- 1970-01-30
著者
関連論文
- 「十勝沖地震における八戸日赤病院の検討」「中層鉄骨鉄筋 (鉄筋) コンクリート造建物の耐震性の研究」に対する谷先生の御質問に対して
- 十勝沖地震における八戸日赤病院 (無被害) の検討
- 中層鉄骨鉄筋 (鉄筋) コンクリート造建物の耐震性の研究
- 中層R.C建物(S.R.Cを含む)の耐震性の研究(第2報)
- 中層R.C建物(S.R.Cを含む)の耐震性の研究