Pin-Restoration の光弾性力学的研究 : 第3報 模型板の外側辺縁から Pin までの距離の影響
スポンサーリンク
概要
- 論文の詳細を見る
The Purpose of this Two-Dimensional Photoelastic studies are based on getting the solution for dynamical answers in planning of pin-restration. The most important factors in pin-restration are length, size, numbers, and location of pins. These factors are Discussed in this investigations. Under the influence of pin length and size for stress concentrations were reported in part I. Under the influence of a space between two pins for stress concentrations were reported in part II. In part III, I studied and discussed about the influence of pin location for stress concentration in specimen. As the results of these efforts, the following conclusionand clinical application are obtained. 1) When appling the compress force on pin axis, the resistance of specimen for load was decreased and the compress stress was increasedin pin apex area. These findings were caused by the pin closer to outer surface, the thickness of specimen became thinner from outer surface to the pin. The stress concentrations under pin apex region were varnished toward the outer surface. Faurther more, the stress fringes were increased in the region off pin apex conected to outer surface. These findings of increased stress in thinn specimen area were indicated that the fracture in this region. From all of these findings and the resultsin part I, I could summarize that increased of the force applied on a pin axis, the pin should be placed in tooth least same distance of pin diameter inside from the outer surface. 2) When appling the perpendicular bending force on pin axis from outer surfacce of specimen, the resistance of specimen for load was decreaied, and the moment of force and spling back action of pin were increased. These findings were caused by the pin closer to outer surface, the thickness of specimen became thinner from outer surface to the pin. The changing of stress concentrations inspecimen was found that the compress stress was increased on the top side pin, and was decreased under side of pin neck. Tensile stress in outer surface of specimen and stress fringes which conected from outer surface of specimen to the top side of pin apex were found. These findings of increased stress in thinn specimen area were indicated that the fracture in this region. From all these findings and the results in part I, I could summarized that in case of the force applied to apin perpendiculary from outer surface to the pin, the pin should be placed in tooth least twice more of pin diameter inside from the outer surface. 3) When appling the perpendicular bending force on pin axis to outer surgace, the resistance of specimen for load was decreased, and the moment of force was increased, also thinn outer surface area getting the bending force directry from piua. These findings were caused by the pincloser to outer surface, the thickness of specimen became thinner from side of pin to outer surface. The compress stress under side of pin neck, top side of apex, and under side of apex were decreased. Tensile stress under side of apex and compress stress in outer surface of specimen were extremely increased within this region. From all of these findings and the results of part I, I could summarized that in case of the force applied to a pin perpendiculary to outer surface of specimen, thepm should be placed in tooth least four times of pin diameter inside from the outer surface. 4) More greater stress concentration was found case of appling the bending force to outer surface of specimen than the same force was applied from outer direction. 5) From all of these findings, the followin conclusion are obtained. Planning of the pin-restration should be discussed about the direction of applied force and the amount of the force, all of these be based upon the sever couadition. In the small pin-restration, the location of pin should be inside from outer surface as same distanceas the diameter of pin. The length of pin snould be least as three times large as the diameter of pin. The size of pin should be least one half of distance between two pins, also increase the number of pins will be decreased the stress concentration in tooth, and will be getting the goodresults on dynamic a view stand point. In the large pin-restration (Post), the diameter of post should be one third of root on all direction. The length of post should be more than three times large as the diameter of post. In such a case, the stress concentration will not be large, also will be getting the good results on dynamic view stand point.
- 社団法人日本補綴歯科学会の論文
- 1974-02-28
著者
関連論文
- 1-6 既製Post. Pinの支台築造への応用 (第67回日本補綴歯科学会学術大会講演要旨)
- 16. ダイベストメント・テクニックに応用されるダウエルピンの1考案 (第60回日本補綴歯科学会講演抄録)
- リバースピン形成に関する研究 : (I) 超音波加工機によるリバースピン形成
- 1B1530 Miniom pinの保持力に関する問題
- Pin-Restoration の光弾性力学的研究 : 第3報 模型板の外側辺縁から Pin までの距離の影響
- Pin-Restoration の光弾性力学的研究 : 第2報 Pin の間隔の影響
- Pin-Restoration の光弾性力学的研究 : 第1報 Pin の長さ・太さの影響
- 19. Pin-Restoration の光弾性力学的研究 : 第2報 Pin の本数と位置について : 特に2本の Pin の間隔が及ぼす影響について (第59回日本補綴歯科学会抄録)
- リバースピン形成に関する研究 : (II) ボール盤式ピンホール穿孔機と超音波加工機とによるリバースピン形成