Analytical Study on Low Concentrations of Gases. VI. Fluorometric Analysis of Chlorine at Low Concentrations in Urban Air
スポンサーリンク
概要
- 論文の詳細を見る
Methods for analyzing low concentrations of chlorine in air are discussed. The use of 0.2% sulfamic acid solution for the collection of chlorine made it possible to sample air in large quantities as much as 2.0 l/min for 60 min. Sulfur dioxide and ammonia, which are interfering gases could be completely removed by the use of a chromic acid scrubber. The color that developed was stable for more than 60 min when the barbituric acid method of Asmus, et al. was employed. Quantitative determination was carried out fluorospectrometrically with a detection limit of 0.03 to 0.04 ppb. A good analytical precision was obtained with a coefficient variation of 5.3% for 6.6×10^<-6> mol of Cl_2.
- 公益社団法人日本薬学会の論文
- 1983-12-31
著者
-
Yashiro Tamotsu
Faculty Of Pharmaceutical Science Nagoya City University
-
Aoyama Taiki
Environmental Pollution Research Institute Nagoya City
関連論文
- Kinetics and Mechanism of the Acid-Base Equilibrium of Mexazolam and Comparison with Those of Other Commercial Benzodiazepinooxazole Drugs(Pharmaceutical)
- Analytical Study on Low Concentrations of Gases. VI. Fluorometric Analysis of Chlorine at Low Concentrations in Urban Air