Numerical Simulation of GM Refrigerator Operating at about 4K
スポンサーリンク
概要
- 論文の詳細を見る
This paper describes the numerical simulation of a GM refrigerator operating at about 4 K. The simulation model is composed of a regenerator, an expansion space, and a cooling stage. The volumetric change of the expansion space and the actual thermophysical properties of the working fluid, helium are considered. The basic equations are mode up of one-dimensional fluid equations and an energy equation of the regenerator material and the cooling stage. The fluid equations are expressed in the general coordinate system of which a coordinate axis moves with time to take account of the volumetric change of the expansion space. These basic equations are differentiated by using the TVD MacCormack method. In order to verify the simulation model, the theoretical validity of the calculation results was checked and calculation results were compared with results of experiments. As a result it was confirmed that the simulation model is appropriate.
- 一般社団法人日本機械学会の論文
- 1999-08-15
著者
-
Nagao Masashi
Mitsubishi Electric Corporation Advanced Technology R & D Center
-
INAGUCHI Takashi
Mitsubishi Electric Corporation, Advanced Technology R & D Center
-
NAKA Kouki
Mitsubishi Electric Corporation, Advanced Technology R & D Center
-
YOSHIMURA Hideto
Mitsubishi Electric Corporation, Advanced Technology R & D Center
-
Yoshimura Hideto
Mitsubishi Electric Corporation Advanced Technology R & D Center
-
Yoshimura Hideto
Mitsubishi Electric Corporation
-
Inaguchi Takashi
Mitsubishi Electric Corporation Advanced Technology R & D Center
-
Naka Kouki
Mitsubishi Electric Corporation Advanced Technology R & D Center
関連論文
- Study on 4K-GM Refrigerator : Effects of Specific Heat of Regenerator Material on Refrigeration Capacity
- Numerical Simulation of GM Refrigerator Operating at about 4K
- Analysis of Transitional Change in Pressure after Quench in Superconducting Generator