軟エックス線拡大撮影法の研究(第35回総会)
スポンサーリンク
概要
- 論文の詳細を見る
It is now generally accepted that clear demonstration of the morphological characteristics of malignant microcalcifications on mammography film is indispensable to obtain precise radiological diagnoses of breast cancer especially in its early stage. Those pathognonic calcifications are actually very minute, their average size are around 0.1mm in diameter. The conventional contact mammography, however, hardly depicts those microcalcifications namely, those smaller than 0.3mm in diameter were usually erazed out mainly because of the geometric blur, of the scattering x-ray and of the quantum mottles of film and intensifying screen. The x-ray exposure doses are another controversial problem in conventional contact mammography especially in the case of mass screening program. They are usually reaching around 1R. of skin dosis per single view of mammography. These high doses of x-ray exposure have been invited by the employment of low sensitivity of recording system which has been employed to avoid unsharpness of mammographic images. The main purpose of this study is to find the appropriate range of characteristics of x-ray to enhance subject contrast of such as breast gland which is consisted of the materials with extremely small x-ray absorption differences each other, and to find the way to eliminate avoidable x-ray scattering to enhance film contrast, as well as to explore the suitable size of focal spot of x-ray tube to be able to clearly demonstrate the majority of the microcalcifications without detrimental geometric blur. Also, some psychological considerations were our concern to increase the diagnostic accuracy rate which can have intimate relationship with the size of the images of microcalcifications. Fortunately, recently available high-speed fine-grain films and rare-earth intensifying screens have been providing us the chance to challenge the study to minimize x-ray exposure doses in mamography ; this circumstance should be added to the study purpose furthermore. The following results were obtained by both fundamental and clinical studies : 1. Magnification power required 2× to 2.5×, to precisely recognize the microcalcifications and other pathognomonic finding of tumor findings of early breast cancer. This range of enlargement technique significantly reduced scattering x-ray to reach films due to "Groedel's effect". 2. The effective focal spot size to be used in the abovely mentioned technique should be smaller than 0.1mm in longest diametert to avoid geometric blur. 3. For standard size of breast, 25kVp was most appropriate tube voltage to produce well contrasted pathognomonic findings. 4. Tungsten anode delivered appreciably ideal quality of x-rays for soft tissue roentgenography. 5. The combination of Lo-D film (Du Pont) and LM screen (Toshiba) showed the best results among other many currently available receptor systems. 6. Target-Film Distance at 70cm was practically most convenient. 7. The skin surface dose in average was 0.43rad. per each projection of mammography. This low range of exposure was made possible by the introduction of high-speed recording system, The graininess of this sort of film and screen was well compensated by the enlargement of images. 8. The clinical diagnosing accuracies significantly improved by the application of this particular technique, especially of the breast and thyroid malignancies.
- 公益社団法人日本放射線技術学会の論文
- 1980-03-01
著者
関連論文
- 乳房軟X線拡大撮影法の研究 : 第7報 希土類増感紙等による描出能の向上と被曝線量の減少
- 乳房軟X線拡大撮影法の研究 : 第6報 頭尾方向圧迫固定拡大撮影法
- 246.乳房軟X線拡大撮影法の研究(第9報) : 拡大撮影の描出能・被曝線量減少の優位性(撮影10 拡大撮影他)(第33回総会会員研究発表)
- 240.甲状腺軟X線拡大撮影法の研究(第1報)(撮影10 拡大撮影他)(第33回総会会員研究発表)
- 17.乳房軟X線拡大撮影法の研究 希土類増感紙について(◇中部部会)
- III.拡大撮影に関する技術的諸問題 : 軟X線拡大撮影について(第32回総会)
- 131.乳房の軟X線拡大撮影法の研究 : 第6報, 軸方向拡大撮影(第32回総会会員研究発表)(撮影-9 拡大・シネ)
- 10.乳房の軟線拡大撮影法について
- 10 乳房の低電圧同位相拡大撮影法(第4回東海北陸部会)
- 乳房の低電圧同位相拡大撮影法
- 66.乳房の低電圧同位相拡大撮影法
- 乳房軟X線拡大撮影法の研究 : 第5報圧迫固定拡大撮影法(内外方向)
- 4.乳房の軟X線拡大撮影法の研究 : 第5報, 圧迫固定拡大撮影法(応用撮影)(第30回総会会員研究発表)
- 9,乳房の軟X線拡大撮影法の研究 : 第5報, 圧迫固定拡大撮影法(◇第8回中部部会)
- 127.乳房の軟X線拡大撮影におけるフィルムおよび増感紙の選定(軟X線撮影)(第28回総会)
- 42.乳房撮影についての検討
- 5.コバルト照射装置用照射野補整具 : 線源容器装着式の試作(東海部会)
- 8〕 コバルト60大量遠隔照射装置による空間的線量分布について
- 65.甲状腺シンチグラムの実大像描記法の研究(第2報)
- 2.甲状腺シンチグラムの実大像描記法の研究
- 78.甲状腺軟X線拡大撮影法の研究(第2報) : 臨床的応用について(第34回総会会員研究発表)(拡大・連続他)
- 座長集約19
- 軟エックス線拡大撮影法の研究(第35回総会)
- 座長集約(第32回総会)
- シンチカメラの陰性腫瘍検出機序の研究 : 第2報検出能を阻害する因子の理論的解析
- シンチカメラの陰性腫瘍検出機序の研究 : 第1報 検出能を阻害する因子の検討
- 164.可変コリメーター : Fill法(R.I.装置)(第30回総会会員研究発表)
- 198.乳房の軟X線拡大撮影の研究(第4報) : 拡大用増感紙MTFによる検討(写真技術(1)感光材料)(第29回総会)
- 168.シンチカメラの陰性腫瘍検出機序の研究(第2報) : 検出能を阻害する因子の理論的解析(RI(3)装置(3))(第29回総会)
- 164.シンチカメラの陰性腫瘍検出機序の探究(RI体外測定(2))(第28回総会)
- 118.シンチカメラの腫瘍検出能について(第27回総会会員研究発表)(R.I2)
- 14.シンチカメラの腫瘍検出能について(第5回東海・北陸部会)
- 98.国産シンチカメラ(ALOKA, RVE-203)の性能及び技術的問題の検討
- 15)レノグラム記録時の技術的諸問題の検討(第3回東海北陸部会)
- 12)^I-T_3resin-sponge uptakeの計測手技による誤差について(第2回東海北陸部会)
- 17)甲状腺シンチグラムの実大像描記法の研究(東海・北陸合同部会)
- 甲状腺シンチグラムの実大像描記法の研究 : 第1報 エネルギー帯域調節法
- 30.試作幼児股関節撮影用固定器とその使用による性殖腺及び介助者被曝量の防御