In radiotherapy, the deliverly of an accurate absorbed dose to target volume in a patient is fundamental strategy. The ICRU Report 29 recommended to achieve the accuracy of ±5% to tumor points for certain type of tumor. Ideally the accuracy should be accomplished all over the target volume rather than a tumor point. The purpose of this paper is to describe an analysis of dose distributions in a target volume. The dose distribution obtained with a conformation technique were used and compared with one of the other technique. Newly developed software on a commercial RTP computer system (CMS, Modulex) calculated dose spectrum, which is similar to the histogram in a target area shown on the ICRU Report 29,in any regions predefined at planning procedures. The extent of dose cocentration to the target volume, the uniformity of doses in the target volume and doses given to normal tissues and to particular organs were obtained by utilizing this dose spectrum. Selected clinical examples were the treatment of cancer of the hypohysis, the maxillary, the esophagus and the pancreas. The conformation technique showed better results than the others with regard to the dose concentration in all cases. As for the dose homogeneity, no differences between two irradiation techniques were observed. Planning procedures in a conformation radiotherapy is not complicate as compared to another techniques, therefore the conformation technique is suitable method for fitting high dose region to the target volume. Use of rotational blocks with the conformation therapy, which are used for selective protection to organs at risk, accomplished the purpose of dose reduction at the organs, however the dose uniformity in a target volume becomes slightly worse. Carefull considerations will be required to avoid the poor dose uniformity in a target volume when a technique for selective protection is planned with another techniques.
- 社団法人日本放射線技術学会の論文
- 1984-09-01
著者
関連論文
- 治療技術委員会, チェックリスト作成班報告
- 63.放射線治療総合計画システムの検討(線量分布データから治療機制御への転送システム)
- 63.放射線治療総合計画システムの検討 : 線量分布データから治療機制御への転送システム(第13回秋季学術大会)
- 47.^Ir小線源に対する線量計算(中部部会(第14回))
- 346.遮蔽用鉛ブロックの設定について(第41回総会会員研究発表)(治療-7 治療計画-1)
- 原体照射機構による二軸振子照射の線量分布と線量評価
- 小型電算機によるラジウム線源の線量分布計算
- 18.原体二軸照射における設定の再現性(治療)(中部部会)
- 9.小型電算機による密封小線源線量計算の実用化(第10回中部部会)
- DECREMENT VALUEの近似計算
- 3.原体照射および打抜照射における照射精度(I.外部照射におけるTarget Volumeへの照射精度)(第40回総会)
- 115.原体二軸振子照射とアイソタイムカーブの応用(治療技術I照射法)(第30回総会会員研究発表)
- 治療計画用電算機による原体照射線量分布の計算 : 第3報 システムの改良と原体照射野に関する基礎的実験
- 治療計画用電算機による原体照射線量分布の計算 : 第二報 原体照射の治療計画システム
- 21.原体二軸振子照射法とアイソタイムカーブの応用(◇第8回中部部会)
- 治療計画用電算機による原体照射線量分布の計算 : 第一報 打抜照射の線量分布計算
- 143.不整形照射野における線量評価(治療(3)線量測定)(第29回総会)
- 線量計算のための近似式の検討
- 136.Iso-time Curveによる原体照射線量分布の近似(治療(2)装置, 線量分布)(第29回総会)
- 195.原体照射線量分布の幾何学的解析(線量測定(2)(照射法))(第28回総会)