Evaluation of Neutron Dose to Radiotherapy Patients Treated with 10 MV X-ray Beams Based on Photoneutron Spectrometry
スポンサーリンク
概要
- 論文の詳細を見る
Neutron dose to radiotherapy patients treated with 10 MV x-ray beams was evaluated based on the spectrometry of incident photoneutrons. Neutron energy spectra could be obtained by unfolding measured responses of neutron capture rates of indium activation foils in a polyethylene phantom with response functions calculated by Monte Carlo simulation. Unfolded neutron spectra inside and outside the x-ray beam indicated that photoneutrons distributed in the energy region of less than 1 MeV with the maximum fluence per unit lethargy at around 0.1 MeV. Effective dose to the patient was adopted as a fundamental protection quantity since photoneutrons from the accelerator head were found to enter the whole body of the patient with approximately flat intensity. Outside the X-ray beam, the dose was evaluated to be 59 μSv/photon Gy from the neutron energy fluence to the effective dose conversion-coefficients tabulated by the ICRP for anterior-posterior irradiation geometry. Since total effective dose received by the patient during the treatment period corresponding to an integral photon dose of 60 Gy was estimated to be as small as 3.5 mSv, no additional shield would be required for contaminant photoneutrons generated by 10 MV therapeutic x-rays.
- 日本保健物理学会の論文
著者
-
IGUCHI Tetsuo
Graduate School of Engineering, Nagoya University
-
Iguchi Tetsuo
Graduate School Of Engineering Nagoya University
-
Aoyama Takahiko
School Of Health Sciences Nagoya University
-
Miyahara Hiroshi
School Of Health Sciences Nagoya University
-
OGATA Yoshimune
School of Health Sciences, Nagoya University
-
Koyama Shuji
School Of Health Sciences Nagoya University
-
Miyata Manabu
Graduate School Of Engineering Nagoya University
-
Ogata Yoshimune
School Of Health Sciences Nagoya University
関連論文
- Neutron Spectrometer for DD/DT Burning Ratio Measurement in Fusion Experimental Reactor
- Development of Dynamic Three-Dimensional Multi-Pinhole Gamma Camera
- Conceptual Design of High-Spatial-Resolution Position-Sensitive Radiation Detector with Single-Electron Transistors
- Measurement of the Induced Radionuclides in Production of Radiopharmaceuticals for Positron Emission Tomography (PET)
- Evaluation of Neutron Dose to Radiotherapy Patients Treated with 10 MV X-ray Beams Based on Photoneutron Spectrometry
- Design Consideration on Compact Neutron Pinhole Camera with Nuclear Emulsion for Energetic-Ion Profile Diagnostics
- Measurement of the Induced Radionuclides in Production of Radiopharmaceuticals for Positron Emission Tomography (PET)
- Neutron Spectrometer for DD/DT Burning Ratio Measurement in Fusion Experimental Reactor