Arc Extinction at a Fixed Short Gap between Silver Electrodes (国際セッションIS-EMD2002〔英文〕)
スポンサーリンク
概要
- 論文の詳細を見る
Arc duration was measured in constant arc gap and constant arc current conditions at silver electrodes. The duration distributes exponentially. The time constant τ and the extinction rate λ of the distribution were calculated, and related to the arc current. It was assured by silver electrode arc that, even below the so-called minimum arc current, arc ignition may occur but, in this case, the arc duration is momentary, and, as the arc current decreases, the arc extinction rate becomes large.
- 一般社団法人電子情報通信学会の論文
- 2002-11-08
著者
-
Suhara Keiichi
Tokyo National Coll. Technol. Tokyo Jpn
-
Suhara K
Tokyo National Coll. Technol. Tokyo Jpn
関連論文
- A Trial to Explain Arc Duration at a Break Contact (国際セッション IS-EMD2005) -- (Arc Discharges & Related Phenomena)
- Arc Extinction at a Fixed Short Gap between Silver Electrodes (国際セッションIS-EMD2002〔英文〕)