EMISSION PROFILE STUDIES OF CRT CATHODES
スポンサーリンク
概要
- 論文の詳細を見る
A cathode emission profiler based on anode-hole scanning method has been developed,which reveals emission density distribution and local emission characteristics in a cathode surface.The 411-type impregnated cathodes with Os-Ru coating for CRT use are studied with this emission profiler having a 2O micrometer anode-hole. Several new findings have been obtained particularly in the aging processes and the oxygen gas poisoning and recovery processes, which imply the importance of emision profile studies in understanding cathodes.
- 社団法人電子情報通信学会の論文
- 1997-02-13
著者
-
Nakanishi Hisao
Uchida Kogyo Co.ltd Tokyo Cathode Laboratory Co.ltd.
-
Tama Masayoshi
Uchida Kogyo Co.ltd Tokyo Cathode Laboratory Co.ltd.
-
Kai Junjirou
Uchida Kogyo Co. Ltd., Tokyo Cathode Laboratory Co. Ltd.
-
Kai Junjirou
Uchida Kogyo Co.ltd Tokyo Cathode Laboratory Co.ltd.