Life of Dispenser Cathodes and Oxide Cathodes in Laminar-Flow Type and Crossover Type Electron Guns (Special Issue on Electronic Displays)
スポンサーリンク
概要
- 論文の詳細を見る
Differences in the behavior of dispenser cathodes and oxide cathodes in laminar-flow type and crossover type electron guns were investigated by experiments and simulations under high-current-density conditions. When an oxide cathode is operated under such conditions, the heating effect due to Joule heat in the oxide layer exceeds the cooling effect, depending on the product of the work function and the cathode current, resulting in a rise in the cathode temperature. This rise in cathode temperature aggravates deterioration of emission characteristics during the life of an oxide cathode. In the case of the dispenser cathode, however, the cathode temperature decrease under high-current-density conditions. When an oxide cathode in a corssover type electron gun is operated, equipotential surfaces are formed in the curved surface in the oxide layer. The formation of an equipotential surface leads to relaxation of the loading. It is considered that this is the reason for the longer life of an oxide cathode in a crossover type electron gun than that of an oxide cathode in a laminar-flow type electron gun.
- 一般社団法人電子情報通信学会の論文
- 1998-11-25
著者
-
Homma Katsuhisa
Material And Component Engineering Dept. Electron Tubes & Devices Div. Toshiba Corporation
-
Higuchi Toshiharu
Material And Component Engineering Dept. Electron Tubes & Devices Div. Toshiba Corporation
-
KAWAHARADA Takahiro
Taishi Works, Toshiba Corporation