A Novel Infrared-Controlled Telephone Communication Interface for the Disabled
スポンサーリンク
概要
- 論文の詳細を見る
This paper reports on the development of an eyeglass-type infrared-controlled telephone communication interface for the disabled. This system is comprised of four major components: A) a headset; B) an infrared transmitting module; C) an infrared receiving/signal-processing module; and D) a main controller, the Intel-8951 microprocessor. The headset with a tongue-touch panel, a wireless earphone, and a wireless microphone. The infrared transmitting module utilizes a tongue touch panel via tongue-touch circuitry which is converted to an infrared beam and a low power laser (<0.1mW) beam. The infrared receiving/signal-processing module, receives the infrared beam and fine tunes the unstable infrared beam into standard pulses which are used as control signals. The main controller is responsible for detecting the input signals from the infrared receiving/signal-processing module and verifying these signals with the mapping table in its memory. After the signal is verified, it is released to control the keys of the telephone interface. This design concept was mainly based on the idea that the use of an infrared remote module fastened to the eyeglasses could allow the convenient control of the dialing motion on the keys of a telephone's dialing-pad which are all modified with infrared receiving/signal-processing modules. The disabled are competent for some of work, such as a telephone operator. The increase of opportunity to do a job for the disabled would help them live independently.
- 社団法人電子情報通信学会の論文
- 1999-10-25
著者
-
KUO Te-Son
Department of Electrical Engineering, National Taiwan University
-
Chen Y‐l
Hwa‐hsia Coll. Technol. And Commerce Taipei Hsien Twn
-
Kuo Te-son
Department Of Electrical Engineering And Graduate Institute Of Biomedical Engineering National Taiwa
-
CHEN Yu-Luen
Department of Electrical Engineering, National Taiwan University
-
SHIH Ying-Ying
Department of Rehabilitation Medicine, Chang Gung Memorial Hospital
-
CHANG Walter
Department of Biomedical Engineering, Chung Yuan Christian University
-
TANG Fuk-Tan
Department of Rehabilitation Medicine, Chang Gung Memorial Hospital
-
WONG May-Kuen
Department of Rehabilitation Medicine, Chang Gung Memorial Hospital
-
Shih Ying-ying
Department Of Rehabilitation Medicine Chang Gung Memorial Hospital
-
Wong May-kuen
Department Of Rehabilitation Medicine Chang Gung Memorial Hospital
-
Chang Walter
Department Of Biomedical Engineering Chung Yuan Christian University
-
Tang Fuk-tan
Department Of Physical And Rehabilitation Medicine Chang Gung Memorial Hospital
-
Tang Fuk-tan
Department Of Rehabilitation Medicine Chang Gung Memorial Hospital
関連論文
- Real-time display of the stomach slow wave and its parameters in a newly designed electrogastrographic system
- A Novel Infrared-Controlled Telephone Communication Interface for the Disabled
- BIOMECHANICAL EVALUATION OF FUNCTIONAL FOOT ORTHOSES WITH CARBON FIBER PLATE-A FINITE ELEMENT ANALYSIS(1C3 Musculo-Skeletal Biomechanics III)
- Pulsed Electromagnetic Fields Accelerate Apoptotic Rate in Osteoclasts