スピーカシステムの前面パネルの振動パターン : 測定条件と結果
スポンサーリンク
概要
- 論文の詳細を見る
This paper is concerned with an experimental modal analysis of a loudspeaker system. Based on Frequency Response Functions (FRFs) measured in about 500 points uniformly spaced on the front panel of the loudspeaker system several vibrations modes of the loudspeaker membranes have been found. Then, the vibrations of the loudspeaker membranes were compared with vibrations of the cabinet of the loudspeaker system. It has been shown that the vibrations of the loudspeaker case were very small relative to the vibration of the loudspeaker membranes. Thus, the loudspeaker cabinet, which may be considered as a set of vibrating plates, is rather a source of a very weak sound and may be neglected. It does not influence significantly on the acoustics field radiated by the loudspeaker system.
- 社団法人日本音響学会の論文
著者
-
Sek Aleksander
Institute Of Acoustics A.mickiewicz University
-
Sek Aleksander
Institute Of Acoustics A. Mickiewicz University Poznan
-
SKRODZKA Ewa
Institute of Acoustics, A. Mickiewicz University
-
Skrodzka E
A. Mickiewicz Univ. Poznan Pol
-
Skrodzka Ewa
Institute Of Acoustics A. Mickiewicz University
関連論文
- 高調波複合音における位相変調の検知限
- 異なる波高率を持つ振幅変調音の検知限
- Simplified method for dead regions diagnosis
- ランダムに振幅と周波数が変化する信号で変調した場合の変調の検知限と臨界変調周波数
- スピーカシステムの前面パネルの振動パターン : 測定条件と結果
- スピーカーの振動モードに対するエンクロージャの影響