New Tube Arrangement of Condenser for Power Stations
スポンサーリンク
概要
- 論文の詳細を見る
Steam pressure loss in a tube bundle significantly influences condenser performance. Based on this fact, a new tube arrangement will be developed. The analytical study shows the advantage of this improvement : up to 20% higher heat transfer performance than from our former design^<(1)>. The method applied to estimate performance is a steam flow analysis using the finite volume method. To confirm the analytical results, hydraulic analogue tests with water are carried out. This new type condenser will be operated in power stations in the near future.
- 一般社団法人日本機械学会の論文
- 1998-08-15
著者
-
Kamada T
Toshiba Corp. Kawasaki Jpn
-
SATO Kenji
Keihin Product Operations, Toshiba Corporation
-
TANIGUCHI Akihiro
Keihin Product Operations, Toshiba Corporation
-
KAMADA Takafumi
Keihin Product Operations, Toshiba Corporation
-
YOSHIMURA Ryoji
Heavy Apparatus Engineering Laboratory, Toshiba Corporation
-
MOCHIDA Yoshio
Heavy Apparatus Engineering Laboratory, Toshiba Corporation
-
Mochida Yoshio
Heavy Apparatus Engineering Laboratory Toshiba Corporation
-
Yoshimura Ryoji
Heavy Apparatus Engineering Laboratory Toshiba Corporation
-
Taniguchi Akihiro
Keihin Product Operations Toshiba Corporation
-
Kamada Takafumi
Keihin Product Operations Toshiba Corporation
-
Sato Kenji
Keihin Product Operations Toshiba Corporation