Influence of Gas Diffusion on Fluid Transient Phenomena Associated with Column Separation Generated during Decompression Operation
スポンサーリンク
概要
- 論文の詳細を見る
A mathematical model is presented for numerical simulation of the fluid transients in the return line during the decompression operation of a hydraulic system. Particular attention has been paid to clarification of the influence of gas diffusion on the fluid transients because in such a system, part of the separation cavity consists of a gas-liquid two-phase flow containing a number of minute gas (air) bubbles. Experiments using sump oil and deaerated oil as a test fluid showed that the generation mechanism of the separation cavity and the fluid transients are significantly affected by the gas diffusion. Values calculated from the proposed "bubble-diffusion model", which takes into consideration the effects of gas diffusion as well as the amount of gas bubbles released from the oil flowing out of the valve before column separation occurs, the change of state of gas and the surface tension applied to the gas bubble, agreed well with the measured values over a wide range of tests.
- 一般社団法人日本機械学会の論文
- 1994-08-15
著者
関連論文
- Characteristics of Fluidborne Noise Generated by a Fluid Power Pump : 4th Report, Pressure Ripple in Hydrostatic Power Transmission
- Fluid Transient Phenomena Associated with Column Separation in the Return Line of a Hydraulic Machine Press
- Characteristics of Fluidborne Noise Generated by Fluid Power Pump : 2nd Report, Pressure Pulsation in Balanced Vane Pump
- Fluid Transient Phenomena Accociated with Column Separation in the Prefill Line of a Hydraulic Machine Press
- Development of an Active Attenuator for Pressure Pulsation in Liquid Piping Systems : Trial Construction of the System and Fundamental Experiments on Attenuation Characteristics
- Development of an Active Attenuator for Pressure Pulsation in Liquid Piping Systems : A Real Time-Measuring Method of Progressive Wave in a Pipe
- Fluid Transient Phenomena Accompanied with Column Separation in Fluid Power Pipeline : 1st Report, On the Horizontal Pipeline Downstream of a Valve Instantaneously Closed
- The Dynamic Behaviour of a Finite Length Straight Pipe Subject to Waterhammer : 1st Report, For Small Elastic Deformation of the Pipe Wall
- Characteristics of Fluidborne Noise Generated by Fluid Power Pump : 3rd Report, Discharge Pressure Pulsation of External Gear Pump
- Influence of Gas Diffusion on Fluid Transient Phenomena Associated with Column Separation Generated during Decompression Operation