DETERMINATION OF ATMOSPHERIC AMMONIA BY ALKALIZED POROUS SILICA BEADS COLLECTION AND CHEMILUMINESCENT NITROGEN DETECTOR-GAS CHROMATOGRAPHY
スポンサーリンク
概要
- 論文の詳細を見る
A simple and rapid method for determination of atmospheric ammonia has been Investigated. The method is based on preconcentration with alkalized Porasil A and on analysis with a chemiluminescent nitrogen detector-gas chromatography(CLD-GC). Collection on and thermal release from the adsorbent are almost quantitative. Prom temperature dependence of retention volumes, it is possible to make a sampling of 5 liters at 20℃, which allows to determine 10 ppb of ammonia in air. Results with the present method are in good agreement with those by the acid collection and the Indophenol method.
- 社団法人日本分析化学会の論文
- 1982-01-05
著者
-
Kirita Kuwako
Training Institute For Environmental Pollution Control
-
KASHIHIRA Nobuyuki
Training Institute for Environmental Pollution Control
-
MAKINO Kazuo
Training Institute for Environmental Pollution Control
-
WATANABE Yoshichika
Training Institute for Environmental Pollution Control