色素Indocyanine Green希釈法による心拍出量測定とその臨床的応用
スポンサーリンク
概要
- 論文の詳細を見る
A new method of serial determination of cardiac output has been employed to evaluate the cardiac function. It is based on the indocyanine green dye-dilution method with sampling from the systemic artery after injection of the dye into the right atrium. The purpose of the present study is to verify the reliability and reproducibility of this method, and to investigate the influence of cardiac glycoside and adrenergic β-receptor blockade upon the cardiac and renal functions, and also to determine the hemodynamic effect of electrical conversion of atrial fibrillation to sinus rhythm in patients with operated mitral stenosis. Part I. The Basic Studies for the Determination of Cardiac Output by Indocyanine Green-Dilution Method Materials and Methods. Indocyanine green in doses of I to 1.5 mg was injected into the right atrium through a 7F Lehman catheter inserted into the antecubital vein. Blood was sampled from the brachial or femoral artery through an indwelling arterial needle employing a Gilford constant withdrawal pump (Model 105S) and a cuvette densitometer (Model 1031R). The dye dilution curve was recorded on an 8-channel photographic recorder (Sanborn 4568A) with an electrocardiogram. The dye concentrations were replotted on a semilogarithmic paper. The curve was calibrated by whole blood and integrated sampling methods. The cardiac output was calculated according to Hamilton's formula. Two successive determinations of cardial indicies within 3 to 5 minutes were made in a total of 31 cases with or without heart disease. Results and Discussion: Fick and dye determination of cardiac output were carried out in 16 subjects. The average dye cardiac index was 2.74 ± 0.20 L/min/m^2 and the Fick was 2.94 ± 0.23 L/min/m^2. The correlation coefficient for Fick to dye was 0.88 (P <0.001). There was no significant difference between the mean values of these two groups. These results showed reliability of the dye method. The average cardiac index in the first determination of the two successive measurements within 3 to 5 minutes in 31 subjects was 2.86 ± 0.15 L/min/m^2. The average in the second determination was 2.88 ± 0.16 L/min/m^2. The percent difference between two successive determinations ranged from -13.3 to ± 10.5%. About 94% of all determinations were within ± 10% of the line of identity. The correlation coefficient was 0.99 (P <0.001). These results revealed good reproducibility of the dye-dilution method. The differences may be mainly due to the physiological changes rather than technical errors.
- 社団法人日本循環器学会の論文
- 1969-12-20
著者
関連論文
- Implantable Pacemaker が奏効したStokes-Adams症候群の2例 : 第21回日本循環器学会近畿地方会総会
- Idiopathic Hypertrophic Subaortic Stenosis(IHSS)の2例 : 診断, 心筋生検および治療
- 特発性心筋症
- 植込式ペースメーカー(implantable pacemaker)使用経験(続報) : 適応, 原因疾患および長期予後
- 2例の左脚ブロックにおけるヒス束エレクトログラム : 第32回日本循環器学会近畿地方会
- 発作性心室頻拍症に対する植込み型ペースメーカー使用経験 : 第32回日本循環器学会近畿地方会
- 収縮性心外膜炎の2例 : 第29回日本循環器学会近畿地方会
- Endomyocardial Bioptomeによる心生検(心バイオプシー)の研究(第2報) : 開胸時針生検および剖検時組織所見との対比(第3報)血行動態との対比
- Acute Coxsackie B Pericarditisの1例 : 第24回日本循環器学会近畿地方会総会
- 有意の心奇型を合併しない成人修正大血管転位症の2例 : 第31回 日本循環器学会近畿地方会
- 拡張期雑音のみを示す動脈管開存症の1例 : 第36回日本循環器学会近畿地方会
- Ebstein's Diseaseの1例 : 第25回日本循環器学会近畿地方会
- 先天性大動脈弁狭窄症の2例 : 第24回日本循環器学会近畿地方会総会
- 粘液水腫心(Myxedema heart)の血行動態と心生検所見 : 第23回日本循環器学会近畿地方会総会
- Endomyocardial Bioptomeによる心生検(心バイオプシー)の研究 : 第4報 : 右室筋の電顕所見
- Late Systolic Murmur Syndromeの1例 : 第28回日本循環器学会近畿地方会
- ストークス・アダムス症候群の1剖検例 : 第22回日本循環器学会近畿地方学会総会
- His束心電図の臨床応用(第4報) : 左軸偏位を伴なう右脚ブロック(LAD+RBBB)
- ヒス束心電図の臨床応用 : (第2報)ヒス束内ブロック(BHブロック)(第3報)sick sinus syndrome(SSS)
- 心機図による心機能の評価(第1報) : 正常値, 心筋症, 甲状腺機能亢進症および低下症
- ヒス束エレクトログラムの臨床応用(第1報) : 心ブロック
- 色素Indocyanine Green希釈法による心拍出量測定とその臨床的応用