A Proposal of Optimal Floor Surface Temperature Based on Survey of Literatures Related to Floor Heating Environment in Japan
スポンサーリンク
概要
- 論文の詳細を見る
Due to comprehensive research on floor heating in Japan and abroad over the last twenty years it is possible today to predict these combinations of comfortable conditions. The specific aim of this investigation is to obtain experimental data upon which the comfortable range of the floor surface temperature could be based, thereby providing a practical and more satisfactory design guide. Accordingly, literatures on floor heating are collected and investigated with the purpose of revealing what the comfort range of floor surface temperature ought to be. Authors tried to obtain a comfortable and permissible floor surface temperature and then reconfirm the maximum comfortable range so that they can propose a reasonable comfortable floor surface temperature and make it fit for practical and extensive use. After synthesizing all the comfortable and permissible values reported in many other papers, this paper finally advances a suggestion on the optimal and permissible floor surface temperatures. Results concerning this subject are as follows. The lowest floor surface temperature would be limited to 25℃, and the highest value to be 31℃. The most optimal temperature for floor surface may as well be within 26〜30℃, and it is 21〜23℃ for the air temperature so that more than 80% subjects can be expected to be comfortable within this recommended temperature interval.
- 日本生理人類学会の論文
著者
-
NAKANE Yoshikazu
Faculty of Sclence of Livlng, Osaka City University
-
Emura Kazuo
Faculty Of Human Life Science Osaka City University
-
Emura K
Faculty Of Human Life Science Osaka City University
-
Zhang L
Shanghai Pulmonary Hospital Shanghai Chn
-
Zhang Ling
Faculty of Human Life Science, Osaka City University
-
Nakane Yoshikazu
Faculty Of Human Life Science Osaka City University
関連論文
- Thermal Environment in a Bathroom
- The Influence of Patterns on the Visibility of Different Floor Levels : Experiment by using Eye-camera
- The Influence of Patterns on the Surface of the Floors upon Sway of the Body
- A Study on the Visibility of Different Floor Levels under llluminane Control : Experiment by using Eye-camera (Part.2)
- Experiment by using eye-camera : A study on the Visibility of Different Floor Levels under Illuminance Contorl
- Study on the Influence ot Aglng on Better Seeing ot Colored Tergets Part 2
- Study on the Readability Valuation of the Inverse Contrast Target
- Thermal Environment in a Bathroom
- Estimations on Contact Temperature with Equipment and Simulation (Part II) Low Temperature Burning on Floor Heating
- Low Temperature Burning on Floor Heating Part I Heat Transfer Analysis for Contact Temperature
- A Proposal of Optimal Floor Surface Temperature Based on Survey of Literatures Related to Floor Heating Environment in Japan
- Problems Related to Thermal Comfort Study in the field of Building Design
- A fundamental study on the quantity of veiling light caused by a highly luminant light source
- Part 1.Case study on the Word-based floors : Relationship between the inpact on several part of the bothIy caused by human gait and the property of fire