H312 PERFORMANCE ANALYSIS OF AN INDOOR HEAT EXCHANGER FOR A CO_2 AIR-CONDITIONER(Thermodynamic analysis/choked flow)
スポンサーリンク
概要
- 論文の詳細を見る
This paper presents the development and verification of a heat exchanger model for evaluating thermal performance of an evaporator for a CO2 mobile air-conditioning system. The model has been developed, based on the finite volume method, with emphasis placed on the air-side heat and mass transfer processes. The governing equations are derived from mass and energy balances using the newly developed air-side heat transfer and friction loss correlations for micro-channel heat exchangers under the dry and wet conditions. The calculated air-side heat transfer and pressure drop data are in good agreement with measured data. However, the refrigerant-side pressure drop estimation for micro-channel tubes usually underestimates the measured value. The simulation results and importance of selecting appropriate heat transfer and pressure drop correlations for the micro-channel heat exchanger are addressed.
- 一般社団法人日本機械学会の論文
- 2000-10-01
著者
-
Kim Man-Hoe
Air Conditioning and Refrigeration Center Department of Mechanical and Industrial Engineering, Unive
-
Bullard Clark
Air Conditioning and Refrigeration Center Department of Mechanical and Industrial Engineering, Unive
-
Kim Man-hoe
Air Conditioning And Refrigeration Center Department Of Mechanical And Industrial Engineering Univer
-
Bullard Clark
Air Conditioning And Refrigeration Center Department Of Mechanical And Industrial Engineering Univer
関連論文
- G312 THERMAL PERFORMANCE ANALYSIS OF SMALL HERMETIC REFRIGERATION AND AIR-CONDITIONING COMPRESSORS(Compressor, special heat pump and others)
- H312 PERFORMANCE ANALYSIS OF AN INDOOR HEAT EXCHANGER FOR A CO_2 AIR-CONDITIONER(Thermodynamic analysis/choked flow)