A115 THERMAL PERFORMANCE ANALYSIS SYSTEM BASED ON MEASUREMENT VALIDATION FOR NUCLEAR POWER PLANT(Advanced thermal system analysis-2)
スポンサーリンク
概要
- 論文の詳細を見る
We have needs to develop a performance analysis system that can be used in nuclear power plant turbine cycle to determine whether or not to tune some equipment and when to replace the equipment. We developed NOPAS (Nuclear Operation Performance Analysis System) to aid robust performance analysis. Robustness in the performance analysis is increased by verification & validation of measured input data. We suggest new algorithm in which estimation relations for valid measurements can be obtained using correlation model between measurements and plant state. The estimation model is obtained using design data and initial acceptance measurement data of nuclear power plant. The model consists of finding most correlated state variables and mapping relations based on the model and the current state of power plant. Using this validation scheme and several adaptations from ASME PTC, we can construct more robust performance analysis system for operating nuclear power plant turbine cycle.
- 一般社団法人日本機械学会の論文
- 2000-10-01
著者
-
Kim Seong
Hoseo University Department Of Mechanical Engineering
-
Choi Kwang
Korea Electric Power Co. (kepco) Kepri Nuclear Power Laboratory