Liquid Holdup and Liquid-to-Particle Mass Transfer for Gas Continuous Two-Phase Flow in Packed Beds
スポンサーリンク
概要
- 論文の詳細を見る
Mass transfer coefficients from liquid phase to particles in packed beds have been investigated for gas continuous two phase flow with a stationary gas phase. Liquid holdup existing in packed beds was obtained by using the method of neutron attenuation and a correlation for liquid holdup was presented as a function of the Reynolds number and the Galilei number. Liquid-to-particle mass transfer coefficients were measured by the limiting current technique. Mass transfer coefficients in two phase flow became greater than those in liquid-full single flow, and were arranged by modifying the Reynolds number and the Sherwood number, considering the actual liquid velocity among particles and the ratio of the mass transfer area to the sectional area of liquid film.
- 一般社団法人日本機械学会の論文
- 1989-08-15
著者
-
Aoki Kazuo
Department of Public Health and Hygiene, Oita Medical University
-
Aoki Kazuo
Department Of Public Health And Hygiene Oita Medical University
-
HATTORI Masaru
Department of Mechanical Engineering, Nagaoka University of Technology
-
Hattori Masaru
Department Of Mechanical Engineering Nagaoka University Of Technology
-
YAMANAKA Naoki
Matsushita Electric Industrial Co., LTD.
-
Yamanaka Naoki
Matsushita Electric Industrial Co. Ltd.
-
Aoki Kazuo
Department Of Aeronautics And Astronautics Graduate School Of Engineering Kyoto University
-
Aoki Kazuo
Department Of Aeronautical Engineering Kyoto University
-
HATTORI Masaru
Department of Mechanical Engineerig, Technological University of Nagaoka
-
Hattori Masaru
Department of Machine Engineering, Tokyo Institute of Technology
関連論文
- Neurophysiological Changes in Rats Subchronically Treated with Styrene or Its Metabolites
- Electrophysiological Changes Induced by Different Doses of 1-Bromopropane and 2-Bromopropane
- Electrophysiological and Biochemical Effects of Exposure to 2, 5-Hexanedione on Peripheral Nerve in Experimental Diabetic Rats
- Evaluation of Cutoff Levels for Screening of Gastric Cancer Using Serum Pepsinogens and Distributions of Levels of Serum Pepsinogen I, II and of PG I / PG II Ratios in a Gastric Cancer Case-Control Study
- Characteristics of Multiple-Pass Heat Exchanger with Melting of Falling Snow(Heat Exchanger)
- Liquid Holdup and Liquid-to-Particle Mass Transfer for Gas Continuous Two-Phase Flow in Packed Beds
- Snow Melting by Heating from the Bottom Surface
- TED-AJ03-373 DRYING OF LAYERED PACKED BEDS
- Characteristics Estimation of Heat Exchangers Operating with Frosting
- Statistical Analysis of Serum Pepsinogen I (PG I) and II (PG II) Levels, PG I/PG II Ratios and Serum Gastrin Levels in a General Population