Heat Transfer in Nucleate Boiling within a Vertical Narrow Space
スポンサーリンク
概要
- 論文の詳細を見る
Pool boiling heat transfer within a confined space was studied for the vertical narrow space between parallel heated and unheated planes. Experiments were performed for water under atmospheric pressure at a heat flux range up to the critical heat flux. The gap size was decreased from 5 mm to 0.15 mm in four steps and two heating surfaces of different heights were tested under the open or closed periphery condition of the narrow space. Based on observed boiling behavior, heat transfer mechanisms were deduced and the heat fluxes calculated by proposed models were compared with experimental data.
- 一般社団法人日本機械学会の論文
- 1988-08-15
著者
-
Fujita Yasunobu
Faculty Of Engineering Kyushu University
-
Ohta Haruhiko
Faculty Of Engineering Kyushu University
-
UCHIDA Satoru
Faculty of Engineering, Kyushu University
-
Uchida Satoru
Faculty Of Engineering Kyushu University
関連論文
- Experimental Study of Forced Convective Heat Transfer in Annular Passage with Axially Varying Cross Sectional Area
- Heat Transfer in Nucleate Boiling within a Vertical Narrow Space
- Heat Transfer in Nucleate Boiling outside Horizontal Tube Bundles : 2nd Report, Prediction for Tube Bundle Effect : Series B : Fluid Engineering Heat Transfer Combustion, Power Thermophysical Properties
- Thermal Control System for Space Experiment on Two-Phase Boiling Flow -II : Manufacture and Test of the Condenser system
- Thermal Control System for Space Experiment on Two-Phase Boiling Flow-I : Analysis and Design of Condenser