1006 家庭用非フロン冷暖房機の開発(FM-4 転換期の課題と対応(2))
スポンサーリンク
概要
- 論文の詳細を見る
Electric heat pumps have been utilized as main residential air conditioners, especially in Japan. They cause a surge in electric power demand during summer and winter. Moreover, the use of HCFCs and HFCs causes serious problems to the global environment ; global warming and ozone sphere destruction. Then we decided it was a top priority task to develop a compact absorption air conditioner for residential use operated by natural gas and without using HCFCs and HFCs. In commercial use, gas-fired absorption air conditioners have a great share. But small ones are very few. The goal was to accomplish the 5 kW (cooling capacity) LiBr/H2O absorption air conditioner within the size of 795H-785W-350D(mm). We had made a lot of breakthroughs with various components, control methods, and materials. We finished the field trials of prototypes successfully and made sure of high performance, reliability, and maintainability. As a result we started to mass-production and released the air-conditioner, "Eco-Life Multi" on June 20th, 1997. Up to Autumn, 1999, over 900 outdoor units of "Eco-Life Multi" had been sold and installed successfully.
- 一般社団法人日本機械学会の論文
- 2000-03-16
著者
関連論文
- 426 家庭用アンモニア吸収ヒートポンプ冷暖房機の技術開発
- 454 ホームコージェネレーション用低温排熱駆動吸収冷凍機の開発 : 吸収冷凍機と室内空調計算の連成シミュレーション(吸収式冷凍機・吸着式冷凍機,環境保全型エネルギー技術)
- 固体高分子型燃料電池を用いた冷温熊取出し型ホームコージェネレーションシステムの検討(エネルギー有効利用(2),空気調和・冷凍・エネルギー有効利用技術)
- 高温濃厚臭化リチウム水溶液中におけるステンレス鋼用の腐食抑制剤
- 吸収冷凍機吸収器の小型・高性能化研究(管ピッチ可変型吸収器を用いた吸収器形状の最適化検討)
- 吸収冷凍機吸収器の小型・高性能化研究(管ピッチ可変型吸収器を用いた吸収器形状の最適化検討)
- 吸収冷凍機吸収器の小型・高性能化研究(水平伝熱管型吸収器の吸収熱交換特性)
- 家庭用アンモニア吸収ヒートポンプ冷暖房機の技術開発
- 1006 家庭用非フロン冷暖房機の開発(FM-4 転換期の課題と対応(2))
- 家庭用吸収式ガス冷暖房システム