PERFORMANCE OF AN ACTIVE MASS DRIVER SYSTEM ON A FIVE STOREY BENCHMARK MODEL
スポンサーリンク
概要
- 論文の詳細を見る
This paper reports the experimental tests conducted on the 5-storey benchmark model defined by Samali [1], using an Active Mass Driver (AMD) system, where the control action is achieved by using Fuzzy Logic controller and UTS state-of-the-art shake table facility. The performance of the Fuzzy controller is checked against Hachinohe 1968,and Northridge 1994 earthquake records as an excitation to the benchmark model. The advantage of the Fuzzy controller is its inherent robustness and ability to handle any non-linear behaviour of the structure. The results of the experimental tests show the ability of the adopted Fuzzy controller to reduce the building responses for the two earthquake records used.
- 一般社団法人日本機械学会の論文
著者
-
Samali B
Univ. Technol. Sydney Nsw Aus
-
Samali Bijan
Center For Built Infrastructure Research Faculty Of Engineering University Of Technology Sydney
-
Al Dawod
Center For Built Infrastructure Research Faculty Of Engineering University Of Technology Sydney
-
Li Jian
Center for Built Infrastructure Research, Faculty of Engineering, University of Technology Sydney
-
Li Jian
Center For Built Infrastructure Research Faculty Of Engineering University Of Technology Sydney
関連論文
- Application of modal-based damage-detection method to locate and evaluate damage in timber beams