BCD-16 DYNAMIC TRANSMISSION ERROR OF SYNCHRONOUS BELT IN CARRIAGE SYSTEM OF SERIAL PRINTER(BELT AND CHAIN DRIVES)
スポンサーリンク
概要
- 論文の詳細を見る
In a serial printer, the printing is carried out line by line, while the print-head moves on papers or other print media. The positioning accuracy in moving time of the carriage, in which the print-head is mounted on, influences the picture quality of printing image directly. Usually, the carriage of serial printer uses a stepping-motor as driving source, and it is driven through meshing transmission elements : a couple of reduction gears and a couple of synchronous belt and pulley. Sometimes density non-uniformity is generated in the printing image, which is called jitter and is a main cause decreasing the picture quality of printing image. It has been found that the positioning error by the meshing vibration of synchronous belt is the most significant factor causing jitter.. In this paper, an theoretical analysis for the motion and vibration of the carriage system is provided, and the vibration displacement of the carriage due to the meshing vibration of synchronous belt, namely the dynamic transmission error, is discussed. The theoretical analysis is confirmed with calculations and experiments.
- 一般社団法人日本機械学会の論文
- 2001-11-15
著者
-
Zhang Weiming
Department Of Mechanical Engineering Osaka Institute Of Technology
-
Koyama Tomio
Department Of Cardiology Ogaki Municipal Hospital
-
Koyama Tomio
Department Of Mechanical Engineering Osaka Institute Of Technology
-
KATANO Keiji
Alps Electric Co., Ltd.
-
Katano Keiji
Alps Electric Co. Ltd.
関連論文
- Adjunctive Stenting after Aggressive DCA with a New IVUS-Guided Method Using Another Directional Guide Wire
- Does Aggressive Thrombolytic Therapy Reduce the Incidence ofNo-Reflow Phenomenon in Patients with Acute Myocardial Infarction (AMI) Who Undergo Angiopalasty?
- Enhanced Washout of I-123 Beta-Methyl-lodophenyl Pentadecanoic Acid (BMIPP) Predicts Good Left Ventricular Functional Recovery after Acute Anterior Myocardial Infarction
- MANGANESE-CONTAINING SUPEROXIDE DISMUTASE IN BLOOD AND URINE DURING OPEN-HEART SURGERY
- Vibration Reduction of a Railway Wheel by Cantilever-Type Dynamic Absorbers : Optimal Adjustment of Absorbers and Experiment
- Spin Wave Spectrum in the Spin-Spiral State of Ferromagnetic Superconductors
- Effect of the angiotensin II type 1 receptor blocker candesartan on cardiovascular events
- Prediction of long-term cardiac events by I123-MIBG imaging after acute myocardial infarction and reperfusion therapy
- Coronary flow response during no-reflow may predict long term LV function and clinical outcome in patients with acute myocardial infarction
- A CASE OF FULMINANT MYOCARDITIS RESCUED : By Long-Term Percutaneous Cardiopulmonary Support
- Hemofiltration Removes Bradykinin Generated in the Priming Blood in Cardiopulmonary Bypass during Circulation
- BCD-20 INFLUENCE OF IDLER ON TRANSMISSION ERROR IN SYNCHRONOUS BELT DRIVES : UNDER TRANSMISSION FORCE(BELT AND CHAIN DRIVES)
- BCD-16 DYNAMIC TRANSMISSION ERROR OF SYNCHRONOUS BELT IN CARRIAGE SYSTEM OF SERIAL PRINTER(BELT AND CHAIN DRIVES)