303 オゾン耐性膜による高効率高度処理 (II)
スポンサーリンク
概要
- 論文の詳細を見る
In order to achieve an efficient and economical advanced drinking water treatment system, relationships between some operational conditions, membrane filtration flux and water qualities were examined by using pilot plant, including unit processes of ozonation, ozone resistant microfiltration (MF) module and granular activated carbon (GAC) tower. From the experimental results, it became obvious that it was necessary to keep residual ozone concentration of more than 0.3mg/L on the membrane surface in order to obtain a high membrane filtration flux. The long term running test was carried out at the flux of 5m^3/m^2/day in the condition of maintaining residual ozone concentration of 1mg/L on the membrane surface with ozone dosage of 2 to 6mg/L. Moreover, quality of the produced water from GAC tower constantly satisfied the Japanese drinking water standard, and removal ratio of odor-causing substances such as 2-MIB and geosmin was more than 99%.
- 一般社団法人日本機械学会の論文
- 2002-07-09
著者
-
中谷 健治
磯村豊水機工
-
森 吉彦
旭化成工業(株) 機能膜技術開発部
-
高橋 和孝
富士電機システムズ(株)水処理統括部
-
峯岸 寅太郎
Jfeエンジニアリング
-
峯岸 寅太郎
日本鋼管
-
高橋 和孝
富士電機
-
森 吉彦
旭化成
関連論文
- 耐オゾン膜と濾過プロセス
- セラミックMF膜を用いた水道用膜ろ過システムの確立(上水・用水技術,大気・水保全技術)
- 沈降促進材を用いる超高速凝集沈澱装置を組み込んだ新しい浄水・排水処理システムの処理性能
- 上水道におけるオゾン処理技術
- 303 オゾン耐性膜による高効率高度処理 (III)
- 303 オゾン耐性膜による高効率高度処理 (II)
- 322 オゾン耐性膜による高効率高度処理
- し尿処理余剰汚泥と生ごみとの混合メタン発酵処理技術
- 浄化槽汚泥対応型し尿処理プロセス
- 耐オゾン膜と濾過プロセス (特集 最近の膜分離技術の展望)
- 塗布法による有機電界発光 (EL) 素子の作製
- オゾン耐性膜
- オゾン耐牲膜及びオゾン併用膜濾過システム