第 1 部 (32) 欠陥を有する原子力用配管の健全性評価手法の開発
スポンサーリンク
概要
- 論文の詳細を見る
The structural integrity of piping in aged power plant is increasingly compromised due to stress corrosion cracking, erosion corrosion and fatigue. The initiation and propagation of these defects require in depth study and some evaluation methods are proposed in this study. To obtain the fatigue crack growth behavior for the surface crack under the residual stress field, fatigue crack growth tests using a welded specimen with a surface crack were conducted and the results were compared with calculation based on the influence function method. Furthermore, four-point bending pipe fracture tests were conducted using full-scale pipe specimens with a through-wall crack or a wall thinning area. The results of these tests were used to propose a low cycle fatigue crack growth evaluation method whereby a simplified ΔJ calculation and a failure mode diagram for evaluation of allowable wall thinning size.
- 一般社団法人日本機械学会の論文
- 2003-03-27
著者
関連論文
- B-45 局部減肉を有する炭素鋼配管の破壊挙動
- 1216 軽水炉中靱性配管に対する Z 係数の策定
- 1215 軽水炉中靱性配管に対する評価不要欠陥寸法の検討
- 2935 欠陥を有する中靭性配管の構造健全性評価 : その 2 延性破壊評価法の検討
- 2934 欠陥を有する中靭性配管の構造健全性評価 : その 1供用中に許容される欠陥寸法の検討
- 2932 オーステナイト系ステンレス鋼の BWR 環境中疲労き裂進展挙動とその評価線図の提案
- 608 軽水炉模擬環境中における炭素鋼の疲労き裂進展速度に及ぼす Rise time の影響
- F-1705 原子力発電プラントの炉内構造物を対象とした応力拡大係数評価手法の検討(S59-2 規格基準の高度化に関連する研究・開発状況(2))(S59 規格基準の高度化に関連する研究・開発状況)
- 第 1 部 (32) 欠陥を有する原子力用配管の健全性評価手法の開発