光ファイバ局所湿度測定装置に関する研究 : 第1報,NBPFシステムおよび検定結果
スポンサーリンク
概要
- 論文の詳細を見る
Two types of systems for measuring local humidity with optical fibers using infrared absorptimetry of water-vapor are proposed and the calibration results are presented. One uses a PbS infrared detector and a beam through 1.86μm narrow band pass filter (NBPF) and another uses a Ge detector and a beam through 1.37μm NBPF. Moist air with known dew-points of 10℃, 15℃, 20℃. 25℃ and 30℃, and with 11 cm, 17 cm, 23 cm and 31 cm optical paths, respectively are used in the calibration test. Apparent absorption coefficients obtained, based on Beer's law, are 0.042 (kPa・m) ^<-1> (the former system) and 0.035 (kPa・m)^<-1> (the latter system) , for different path lengths and the accuracy of the present measurements are estimated to be±1.1 g/m^3 (the former system) and ±0.7 g/m^3 (the latter system) for a 31 cm optical path. These results show that the latter system is more accurate at the present state and that the NBPF system is nearing a practical application.
- 一般社団法人日本機械学会の論文
- 1987-01-25
著者
関連論文
- 非ニュートン流体への自然対流熱伝達の実験的研究
- 非ニュートン流体への自然対流熱伝達の実験的研究
- 一様発熱鉛直面から空気への層流自由対流熱伝達 : 固体ふく射を考慮した場合
- サタバイ模型非ニュートン流体への自然対流熱伝達の数値解析
- Sutterby模型非ニュートン流体への自然対流熱伝達の数値解析
- 光ファイバ局所湿度測定装置に関する研究 : 第1報,NBPFシステムおよび検定結果
- 鉛直平板から熱と物質の同時移動を伴う自由対流 : 熱伝達係数と物質侯達係数に関する近似式
- 光ファイバ局所湿度測定装置に関する研究 : 第2報,局所湿度変動の実測およびタプルビーム・システムの検討