遠心ファンの羽根なしディフューザ内の旋回失速に関する研究 : 第2報,圧力変動の分析
スポンサーリンク
概要
- 論文の詳細を見る
The unique peripheral distribution of the amplitudes of pressure fluctuations on a diffuser wall was observed under the rotating stall of a diffuser. The distribution changed according to the number of cells for the same scroll. The reason why the distribution occurs is not evident. A study is carried out to clarify the principal cause for the unique distribution. The instantaneous pressure distributions on the diffuser wall are measured and they are analized by the authors' original technique. The measured pressure fluctuation is separated into two components and the factors for the above unique distribution are made clear. The mechanism of the occurrence of the unique distribution is clarified by the experiment and the numerical analysis. Some interesting facts observed in the experiment are also presented.
- 一般社団法人日本機械学会の論文
- 1987-03-25