A thermal efficiency of heat engine systems is generally evaluated as the ratio of the available net work to be taken out from the system to the fuel energy into it. In usual systems such as steam cycle or combined cycle, the evaluation stated above is reasonable one. However, in Waste-to-Energy systems to be combined with gas turbine and steam turbine, which are named as Super-WTE in Japan, the evaluations to be usually used are not always reasonable one. Author has newly defined the ratio of the power increase to the inputted gas turbine fuel energy as repowering efficiency. In this paper, the reason that the usually used thermal efficiency is not reasolable on evaluation of combined WTE system has mentioned and the relationships between the repowering efficiency versus gas turbine capacity and its pressure ratio have been studied.
- 一般社団法人日本機械学会の論文
- 1999-12-25
著者
関連論文
- P15-09 20MW 級ガスタービン (Kawasaki L20A) を用いた高効率コンバインドサイクルプラントシステムの開発
- コンバインド方式スーパーごみ発電システムの性能評価
- 中小容量ガスタービンコージェネレーション用排熱回収ボイラ(複合発電システムに必要な関連設備)