パイプラインの過渡応答計算による漏えい位置の検知
スポンサーリンク
概要
- 論文の詳細を見る
This paper describes a method for estimating the position of a detected leak by applying a fluid transient model to a real-time pipeline system. The method takes account of flow rate and pressure profiles along a pipeline in a transient condition based on an assumption of quasi-steady-state flow. The result of casestudies using a hypothetical gas pipeline system shows that, even in a transient condition, the method gives a more accurate estimation of a leak position than conventional methods which do not consider flow rate or pressure profiles along a pipeline. The method is also applicable to a pipeline having consumer stations which cause abrupt changes of flow rate profile along the pipeline. Furthermore, the influence of instrument errors on the result of the method is discussed. The result also shows that the method is more accurate than the conventional methods.
- 一般社団法人日本機械学会の論文
- 1991-09-25
著者
関連論文
- パイプラインの過渡応答計算による漏えい位置の検知 : 第2報, 実験による検証
- 垂直落下液膜における流下方向の流動変化
- 垂直落下液膜における流下方向の流動変化
- 陰解法によるパイプライン網の過渡応答計算
- パイプラインの過渡応答計算による漏えい位置の検知
- 節点解析法による管路網の定常流計算