On the Water Swelling Phenomena of Once-through Boilers
スポンサーリンク
概要
- 論文の詳細を見る
During start-up of a once-through boiler plant, the so-called water swelling phenomena (Wasserpfropfen) occur, which large quantities of water are simultaneously discharged from the boiler and flow into the by-pass circuits. In this report we first of all suggest a calculation method using an electronic digital computer which incorporates assumptions approximating the actual conditions. Numerical calculations are then performed by this method, and the effects of various factors on the water swelling phenomena are made clear. We also report the test results at the 75 MW Shin-Shimizu Thermal Power Station, which has the first large-size commercial Benson boiler in Japan.
- 一般社団法人日本機械学会の論文
著者
-
HOSOKAWA Yoshikazu
Hitachi Research Laboratory
-
Hosokawa Yoshikazu
Hitachi Research Laboratory Hitachi Ltd.
-
TAMURA Zensuke
Hitachi Research Laboratory, Hitachi, Ltd.
-
SAKAI Akira
Hitachi Works, Hitachi, Ltd.
-
Tamura Zensuke
Hitachi Research Laboratory Hitachi Ltd.
-
Sakai Akira
Hitachi Works Hitachi Ltd.
-
Tamura Z.
Hitachi Research Laboratory, Hitachi, Ltd.