Accuracy of Oil Immersion Gear Loss Measuring Formula
スポンサーリンク
概要
- 論文の詳細を見る
This paper makes the discussion on the accuracy of measuring gear loss by Oil Immersion Formula, in which the temperature of the oil steeping test gear is measured. The conclusions are as follows : (1) There are some suitable time intervals for measuring oil temperature. At 17.75 rps, for instance, it was considered appropriate to begin the interval counting began one minute after starting. (2) In the test stand, bearings were set up in the wall of the oil tank, in which gears were to run. The bearing heat generated by gear load had no influence on oil temperature. (3) The measured gear loss values were not affected by the oil viscosity that varied in accordance with the temperature rise during operation. (4) Oil Immersion Formula is superior in accuracy to the conventional method using a power circulating gear testing machine.
- 一般社団法人日本機械学会の論文
著者
関連論文
- Planetary Ball Drive Mechanism : Shape of Scoop Surface of Ball and Test Result
- Accuracy of Oil Immersion Gear Loss Measuring Formula
- Relation of Frictional Loss of Gear to Speed and Torque
- Continuously Variable Transmission Using 2-degrees-of-freedom Epicyclic Gear and Unbalance Mass