On the Flow of the Air-Water Mixture in the Branch Pipe : 1. Experiment on the Horizontal Branch Pipe Which is Equal to the Main One in Diameter
スポンサーリンク
概要
- 論文の詳細を見る
Authors experimented on flow patterns, distribution of quantity, especially loss of head at a cross-branch section by flowing air-water mixtures into a horizontal branch pipe of 23.4 mm in dia. They carried out the investigation from the following two view-points : (1) ξ_<b_1>, loss of energy attributable to the branch only. (2) ξ_<b_2>, loss of energy including the effect of the irregularity of the stream past a branch section. In consequence, it was possible for them to make the characteristics of the loss of energy comparatively clear. Then they discovered that the coefficient of loss of head ξ_<b_2>' was approximately proportionate to the ratio of energy at the main flow and the branch flow.