On the Flow in the Impeller of Centrifugal Compressor with Inducer
スポンサーリンク
概要
- 論文の詳細を見る
An analysis of a flow through the impeller of a centrifugal compressor which consists of inducer and radial vanes, is presented. The three-dimensional flow through the actual impeller is replaced by a two-dimensional inviscid subsonic flow model. The numerical calculation is carried out by the use of the singularity method. Influences of parameters, that is, Mach number of the rotational speed, impeller width ratio, dimension of the inducer etc. upon the impeller performance and upon the velocity distribution along the blade are investigated.