Variation of Heat Flux through a Combustion Chamber Wall of Pre-chamber type Diesel Engine : Heat Flux through Piston Crown, Cylinder Head, Suction Valve, Exhaust Valve, Pre-combustion Chamber and Exhaust Port Wall
スポンサーリンク
概要
- 論文の詳細を見る
The heat flux through the combustion chamber wall varies periodically with thermodynamical cycle of engine and locally according to various places of the wall. In this research project the heat flux was measured at the walls of piston crown, cylinder head, suction valve, exhaust valve, pre-combustion chamber and exhaust port, and the result was compared with the calculated value of heat loss based on cooling water. The heat flux at any point and at any period during the cycle depends on gas temperature, the surface temperature of wall and gas flow. Especially, it is affected by a jet flow from the pre-chamber and the arrival of a burning flame at these points. The percentage of heat loss from piston crown is about 7%, from cylinder head 4%, from prechamber wall 4%, from suction valve 1%, from exhaust valve 0.5% and from exhaust port 5% of the heat energy supplied by fuel at full load.
- 一般社団法人日本機械学会の論文
著者
-
Harigaya Yasuo
Faculty Of Engineering Saitama University
-
Yoshida Masaichi
Faculty Of Engineering Saitama University
-
Sato Kaoru
Isuzu Motors Limited
-
Sato Kaoru
Isuzu Advanced Engineering Center, Ltd., Fujisawa, Kanagawa 252-0881, Japan
関連論文
- Variation of Heat Flux through a Combustion Chamber Wall of Pre-chamber type Diesel Engine : Heat Flux through Piston Crown, Cylinder Head, Suction Valve, Exhaust Valve, Pre-combustion Chamber and Exhaust Port Wall
- Effects of Cluster Size on Platinum--Oxygen Bonds Formation in Small Platinum Clusters