Measurement of the Snow Fraction in a Snow/water Mixture Flow in a Pipe
スポンサーリンク
概要
- 論文の詳細を見る
A method was proposed to determine the snow fraction from the hydraulic gradient of a snow/water mixture flowing in a vertical pipe with a circular cross section. Experimental results showed that the mixing of snow did not affect the frictional force on the vertical pipe wall, and that the volume snow fraction C' in the pipe was nearly equal to the value C at the discharge. Based on these results, it was confirmed that C' was determined within an error of 2% by the method proposed here for the pipe diameter D corresponding to the range of Froude numbers Fr between 5 and 35 [Fr=U_m^2/(|1-s|gD) , U_m;flow velocity, s;density ratio of ice to water, g;gravity acceleration.
- 一般社団法人日本機械学会の論文
著者
-
Shirakashi Masataka
Technological University Of Nagaoka
-
KOSHIO Atsushi
Matsushita Electronics Corporation, Kyoto Research Laboratory
-
WAKlYA Shoichi
Technological University of Nagaoka
-
Koshio Atsushi
Matsushita Electronics Corporation Kyoto Research Laboratory
関連論文
- Vortex Excited Oscillation of a Circular Cylinder in a Uniform Flow
- Analysis of Turbulent Structure of an impulsively Started Jet by Applying Image Processing
- Effect of Plate Wall above a Pipe Inlet on the Entry Flow of Viscoelastic Fluids
- The Structure of Turbulent Diffusion : 2nd Report, Diffusion near the Turbulent Interface
- Measurement of the Snow Fraction in a Snow/water Mixture Flow in a Pipe
- Error in Concentration Measurements Using Sampling Probes