A study of Allowable Piping Loads on Double-suction Centrifugal Pumps : 3rd Report, Slip of Pump Feet Caused by Piping Load
スポンサーリンク
概要
- 論文の詳細を見る
The slip of pump feet on the baseplate caused by piping loads was investigated. The test pump was axially-split, single-stage double-suction volute type with foot support. The static coefficient of friction between the pump foot and baseplate ranged between 0.15 and 0.35. The effects of dowel pins and jack screws on the slip were also investigated. Shaft displacements due to the deformation of pump casing and baseplate were measured. In the case test pumps, the proportion of the shaft displacement due to the casing deformation to that of pump assembly was 50% and more in most load conditions. Then, the rigidity of not only the baseplate but also the pump casing must be increased when large piping loads over API loads are specified.
- 一般社団法人日本機械学会の論文
著者
関連論文
- A Study of Allowable Piping Loads on Double-suction Centrifugal Pumps : 1st Report, Casing Stress Distribution Produced by Piping Loads with Added Internal Pressure
- A Study of Allowable Piping Loads on Double-suction Centrifugal Pumps : 2nd Report, Shaft Displacement Due to Pump Casing Deformation
- A Study of Ceramic Bearing for Vertical Pumps : Friction Coefficients of Submersible Bearings in Air and Water
- A Study of Ceramic Bearing for Vertical Pumps (Wear of a Submersible Bearing in Slurry)
- A study of Allowable Piping Loads on Double-suction Centrifugal Pumps : 3rd Report, Slip of Pump Feet Caused by Piping Load